Fixation of the Angio ergometer to a wall

In this system, the Angio is fixed to the wall. Handgrips are standard included.
The Angio is an ergometric unit that can be used for both arm and supine ergometry. Its compact design makes it universally applicable for ergometric studies in those sectors in which standard ergometry cannot be used. The Angio operates independent of pedaling speed in the range of 7 - 1000 watt. For communication with ECG-devices or PC, both RS232 and analog interfaces come standard with the ergometer. The external control unit has one display unit showing multiple ergometry parameters (free adjustable).
Overview

Highlights
Easy to operate
For Lode products this means:
- easy to connect
- easy to move around
- easy user interface
Features
7 Watt start-up load
Extreme low start-up load
The extreme low start-up load of 7 watts and the adjustability in small steps of 1 watt make this ergometer perfectly suitable for many different applications. The standard control unit shows multiple ergometry parameters and you can determine your specific default setting and start-up menu.
Specifications

Workload
Maximum continuous load 750 W the maximum power the ergometer can deliver continuous
Linear workload control yes control ergometer in a linear way
Hyperbolic workload control yes control of workload in hyperbolic way
Maximum peak load 1000 W the maximum load the ergometer can provide for a short period of time
Maximum rpm independent constant load 150 rpm rpm as to which constant load can be applied
Dynamic calibration yes continuous calibration during application of workload
Electromagnetic "eddy current" braking system yes system that very accurately applies a brake to the ergometer
Fixed torque workload control yes control ergometer in a fixed torque way
Minimum load 7 W the minimum load the ergometer can provide
Minimum load increments 1 W the smallest steps with which the load can be added
Minimum rpm independent constant load 30 rpm rpm as from which constant load can be applied
Optional heart rate controlled workload yes control the device optionally through a set heartrate
Accuracy
Workload accuracy from 7 to 100 W 3 W accuracy of the ergometer between 7 and 100 Watt
Workload accuracy from 100 to 500 W 3 % accuracy of the ergometer between 100 and 500 Watt
Workload accuracy from 500 to 1000 W 5 % accuracy of the ergometer between 300 and 1000 Watt
User Interface
Analog operation mode yes operate analog
Manual operation mode yes operate manually
External control unit yes a control unit is connected with a cable to the ergometer
Preset protocol operation mode yes operate via preset protocols
Selfdesigned protocol operation mode yes operate via sefdesigned protocols
Terminal operation mode yes operate with an external device
Connectivity
Analog connector yes read-out of ergometer load in an analog way
Dimensions
Product height 73 cm 28.7 inch height of product
Product length 61 cm 24 inch length of product
Product weight 37 kg 81.6 lbs the weight of the product
Product width 42 cm 16.5 inch width of the product
Power requirements
115 V AC 50/60 Hz (130 VA) yes operational power
230 V AC 50/60 Hz (130 VA) yes operational power
Standards & Safety
ISO 9001:2008 compliant yes Lode fulfills ISO 9001: 2008 requirements
ISO 13485:2003 compliant yes Lode fulfils ISO 13485:2003 requirements
IEC 60601-1 compliant yes the product is IEC 60601-1 compliant
Accessories

Support

FAQ

Q - Is it possible to request RPM and Load data through the RS232 port while cycling in Manual mode.

Yes you can request the actual pedalling speed and power when you are cycling in Manual, Analogue or Terminal mode.
The load will only be returned when the pedalling speed is 30 RPM or more. For technical details see the Lode RS232 protocol

Part number
  • 917902

Brochures
Brochure Arm Ergometry German
Brochure Arm Ergometry Dutch
Brochure Arm Ergometry English


Interfacing protocols
BTL
CareFusion
Cognimed
Cortex
Delmar Reynolds
Edan Instruments Inc.
Enverdis GmbH
ET Medical
GE Healthcare
Labtech
Lode
Med-tronik
Medical Graphics
Mesa Medizintechnik
Mortara
Nihon Kohden
Norav
nSpire Health
Parvomedics
Philips Medical
Progetti
Pulse Biomedical, Inc.
Quinton
Schiller
Seiva
Welch Allyn

1550K
600 USB system
9320K
AT-10
AT-104 PC
AT-110
AT10 Plus
BreezeSuite Software
BTL-08 ECG
Cardiax PC-EKG
Cardio Collect 12
Cardiologic Explorer 12C Ergo
CardioPerfect
Cardiosoft
Cardiosoft MAC 1200 ST
CS200
Cubestress
EC12 R/S
Edan EC-12 EXPRESS
Edan ST-1212 STRESS ECG
Ergolog
GE Case
GE Case 8000
GE Case Basic
GE Case Performance
GE Case Premium
GE Case Value
Lactware Software
Lode Ergometry Manager
MAC 5000
MAC 5500
MasterScreen® ECG / Viasys Oxycon Pro
Metasoft
Multi Control
MyStress system
PC ECG 1200
Q-Stress
QRS-card
StressVue
TM Cardio 1000/2000
TrueOne
X-scribe
XR-200